WIDE BAND MAGNETOTELLURIC STATION LEMI-419 FOR FIELD SURVEY

Main features:

bulletModular construction
bullet3 magnetic field components measurements
bullet4 telluric field channels
bulletWide frequency range (DC…200) Hz
bulletSatellite timing
bulletExcellent temperature stability
bulletHigh suppression of industrial noise
bulletLow noise level
bulletSpecial software and calibration
bulletReal-time data acquisition and visualization
bulletDigital interface

LEMI-419

 

Wide band magnetotelluric station LEMI-419 is intended for the study of natural electromagnetic fluctuations in the frequency band 0.0001-200 Hz in field conditions. The station maintains automatically measurements in wide temperature range and digitizing data from 3 search-coil magnetometers, 4 telluric channels and monitors the temperatures of sensor and electronics. The real time acquisition, recording and visualization of current and previously recorded data are executed at an external computer to which digital data are transferred through serial RS-422 port. The station operation is synchronized with GPS timing.

 

MAIN TECHNICAL PARAMETERS

1. Search-coil magnetometer

Frequency band (0.0001-200) Hz
Shape of transfer function linear-flat
Corner frequency  (or other on demand) 1 Hz
Transfer factor at flat part  (or other on demand) 20 mV/nT
Noise level:
at 0.001 Hz

at 0.01 Hz
at 1 Hz
at 100 Hz
< 100 pT/√Hz
< 10 pT/√Hz
< 0.1 pT/√Hz
< 0.01 pT/√Hz
Weight of the sensor 5.8 kg

2. Electric field meter

Frequency band (DC-200) Hz
Measuring ranges (for measuring base 1 m):
at gain=1
at gain=1
0
at gain=1
00
at gain=1
000
± 7500 mV
± 750 mV
± 75 mV
± 7.5 mV
Offset compensation range ± 7500 mV
Noise level in frequency band  (0.01- 0.3) Hz     0.1 μVrms
Non-polarized electrodes own noise in  frequency band (0.01…0.3) Hz < 10nV

3. Electronic unit

Power supply voltage (9-18) V
Power consumption 6 W
Weight < 4 kg
Operation temperature range minus 20 °C to +60 °C

Waterproof housing